Reed Mini Float Level-Sensor
The mini sensor is the smallest sensor for continuous fill-level monitoring and functions in accordance with the Reed chain principle. It is particularly suited for use in confined spaces and with small containers. Using very small floats, measurements can be carried out practically to the bottom of the container. Reed Electronics has a large range of materials and components and will find the right solution for your application.
The tried-and-tested miniature sensors are used, for example, to measure residual fluids in analytical instruments or in the chemicals industry, meaning that a process can be automated and optimised.
- Miniaturised level-sensors
- Enclosed and robust Reed chain
- Customer-specific production with no minimum order quantities
- Wide range of materials
- Customer-specific electrical and mechanical connections
- Measuring grid resolution of 5 mm
- Available in an optional food design (electropolishing process)
- Available in an optional EX design
- Can be combined with temperature switches or PT100 / PT1000
- Reliable
- Free from wear and tear and no maintenance required
- Simple installation
- No programming necessary
TECHNICAL SPECIFICATIONS
-
Mechanical connections
G1/8", G1/4", G3/8", G1/2", G1"
(optional incl. counter nut) -
Mechanical materials
PVC, PP, PVDF and stainless steel
-
Float materials
PVC, PP, PVDF and stainless steel
-
Float dimensions
Ø 16–27 mm
-
Tube dimensions
Ø 8 mm
-
Sensor length
100–1,000 mm
-
Installation types
From the inside, from the outside or an inverted installation
-
Installation position
Max. 30°
-
Section of measurements
100–1,000 mm
(dependent on the float and the grid dimensions) -
Measuring grid
5 mm
-
Electrical connections
Socket, cable, plug-in connector or as per a specific customer request
-
Socket materials
Aluminium and polyamide
-
Cable materials
PVC, PUR, silicone, Teflon, FEP or as per a specific customer request
-
Output signal
Resistance Ω, Current 4–20 mA, Voltage 0–10 V
-
Temperature range
-20°C to 110°C
(dependent on the float and the materials) -
Pressure range
Must not be used as a safety-relevant limiting device within the pressure range.
P max. upon request; the pressure range is always dependent on the float.. -
Protection class
Up to IP68
-
Approvals
EX design, food (electropolishing process)
-
Assembly
Can be installed in assemblies
-
Note
The sensors are based on a modular design and can be assembled individually.
The Reed switches used are also enclosed in individual plastic housings to ensure greater robustness.
Contact us.
We will find the right solution and would be happy to provide you with advice.